vialroom

#coa-reading 2024-09-20

Friday29 messages7 participantstimes are UTC
Highlights from this day
  • truncation_tru — tfa or acetate, how do i tell from the paperwork 19:09
  • triple_ag_tom — the certificate from TFC is the one i use to teach this because it actually has a populated impurity table 20:00
  • snac_and_water — an identical chromatogram on two different lots is the single biggest tell there is 20:30
  • snac_and_water — a lab that reports "greater than 98%" rather than a number is telling you they did not integrate carefully 20:35
18:44truncation_tru joined
HH

genuine question single wavelength detection can miss a co-eluting impurity that does not absorb there

TT

tfa or acetate, how do i tell from the paperwork

peak   RRT    area%    note
  1   0.42     0.31    solvent front
  2   0.88     0.44    related substance
  3   1.00    98.72    main
  4   1.14     0.53    related substance
HH

mixed fonts and inconsistent kerning in one document is worth a second look, n of 1 obviously
no lot number, no certificate. a document you cannot tie to the vial in your hand is decoration

[edited]
SA

tfa counterion runs higher by mass than acetate. if the certificate does not say, you cannot do the mass balance

VB

Digest for the week of 2024-07-18 has been published.

Testing queue: 7 submissions open, 108 awaiting dispatch.

⚠️3😂4
PS

while im here is endotoxin ever tested on research material

PS

is sterility tested as part of a normal purity certificate

TA

net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial

HH

update on the earlier thing i have never seen a research certificate with an endotoxin result on it. not once

PS

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not, not advice obviously

HH

coming back to this the three way match is vial, certificate, invoice. if all three agree you have something

the related substances table is the interesting part. a row of "not detected" means they did not look hard

what does net peptide content mean next to gross mass

looks re-dated

i asked SSA for the method and they sent it. that alone put them ahead of most, for what its worth

thats a real table

*that should say weekly

update from 4 months ago: started asking every supplier for water content and about half now include it

SA

an identical chromatogram on two different lots is the single biggest tell there is

⚠️1🤝7🙏5

a lab that reports "greater than 98%" rather than a number is telling you they did not integrate carefully

❤️102🧊1