vialroom

#coa-reading 2025-01-17

Friday39 messages7 participantstimes are UTC
Highlights from this day
  • slow.taper — i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019 14:57
  • LC_MS_Lena — is endotoxin ever tested on research material 15:22
  • chaser_chris — gross mass on a jewellery scale plus the water content is enough to catch most underfills 15:25
  • slow.taper — one decimal versus two is usually just house style, not precision 16:20
LM

a vial can be 99.4% pure and hold 8.1mg of a 10mg label. both numbers are true and only one of them is the one you care about

VB

On this day 4 years ago this channel logged 91 messages.

ST

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019

🔥13😂214
LM

certificate is dated before the lot date, is that just sloppiness

mixed fonts and inconsistent kerning in one document is worth a second look

is endotoxin ever tested on research material

🎉12👀13

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not

CC

gross mass on a jewellery scale plus the water content is enough to catch most underfills

lot        bought    purity   assay/label
A-2418     2025-03   99.1%    9.6 / 10mg
A-2601     2025-08   98.7%    9.8 / 10mg
B-0114     2026-01   99.3%    9.4 / 10mg
B-0329     2026-04   98.9%    9.9 / 10mg
CC

residual solvents matter more than people think for anything that went through a lot of purification steps

CC

nobody can authenticate a certificate from a scan. you authenticate the material by testing it yourself

update from 16 months ago: started asking every supplier for water content and about half now include it

ST

tfa counterion runs higher by mass than acetate. if the certificate does not say, you cannot do the mass balance

CC

ok so net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial

❤️1
ST

one decimal versus two is usually just house style, not precision

📉13🙏10🔥1
CC

unrelated but no lot number on this certificate, does that make it worthless

CC

is area percent the same thing as how many mg are in the vial

😂9

two certificates from the same supplier have an identical chromatogram, is that normal

whats the minimum a certificate has to have before you take it seriously

TT

my 40mg vial weighed more than 5mg of powder, is the certificate lying

slightly off topic but a certificate should name the method, the instrument, the column and the operator. most name none of those

good certificate actually

the honest summary is that a certificate tells you what the supplier says about a lot they chose to test, we shall see

🙏1🧪3📉2

check the lot

not detected means nothing

if you only read one line on a certificate, read the lot number. if you read two, read the assay

CC

unrelated but i asked MKM for the method and they sent it. that alone put them ahead of most

VI

sterility and endotoxin are separate tests and almost nobody runs either on research material

VI

unrelated but the paperwork can be perfect and the vial can still be light. weigh it, not advice obviously