mixed fonts and inconsistent kerning in one document is worth a second look
#coa-reading 2025-05-05
Monday9 messages4 participantstimes are UTC
Highlights from this day
- crimp_top — the font on this one changes halfway down, am i being paranoid 20:25
- crimp_top — update on the earlier thing a vial can be 99.4% pure and hold 8.1mg of a 10mg label. both numbers are true and only one of them is the one you care about 20:32
- crimp_top — the three way match is vial, certificate, invoice. if all three agree you have something 20:33
- alcohol_hits — right so retention time shifts between runs are normal. relative retention time is the number to compare, we shall see 20:37
the font on this one changes halfway down, am i being paranoid
peak RRT area% note
1 0.42 0.31 solvent front
2 0.88 0.44 related substance
3 1.00 98.72 main
4 1.14 0.53 related substancenot evidence on its own
[edited]🔥1📈5
update on the earlier thing a vial can be 99.4% pure and hold 8.1mg of a 10mg label. both numbers are true and only one of them is the one you care about
the three way match is vial, certificate, invoice. if all three agree you have something
📈15❤️1📉17
the retention time on this one is different from the last lot, problem
right so retention time shifts between runs are normal. relative retention time is the number to compare, we shall see
should a certificate say which instrument and method they used
coming back after 10 months, has the pinned reading guide changed