single wavelength detection can miss a co-eluting impurity that does not absorb there
#coa-reading 2025-05-21
- dexa_or_bia — the retention time on this one is different from the last lot, problem 22:13
- area_percent — sorry to jump in mixed fonts and inconsistent kerning in one document is worth a second look 22:19
- truncation_tru — genuine question the font on this one changes halfway down, am i being paranoid 22:31
- chain_of_custody — quick one purity is what fraction of the contents is the target. assay is how many mg are actually there. different questions 22:52
looks re-dated
ok so the honest summary is that a certificate tells you what the supplier says about a lot they chose to test
should a certificate say which instrument and method they used
net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial
is water content normally on a certificate or do you have to ask
the related substances table is the interesting part. a row of "not detected" means they did not look hard
the retention time on this one is different from the last lot, problem
purity is not assay
sorry to jump in mixed fonts and inconsistent kerning in one document is worth a second look
no lot no certificate
same chromatogram
genuine question the font on this one changes halfway down, am i being paranoid
two certificates from the same supplier have an identical chromatogram, is that normal
i asked GL Biochem for the method and they sent it. that alone put them ahead of most
the certificate from FGP is the one i use to teach this because it actually has a populated impurity table
coming back to this if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not, i think
good certificate actually
quick one purity is what fraction of the contents is the target. assay is how many mg are actually there. different questions
water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it
i have never seen a research certificate with an endotoxin result on it. not once
i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019
check the lot
is sterility tested as part of a normal purity certificate
weigh the vial
tfa counterion runs higher by mass than acetate. if the certificate does not say, you cannot do the mass balance
sloppy not sinister
for the archive certificate is dated before the lot date, is that just sloppiness
test it yourself
slightly off topic but whats the minimum a certificate has to have before you take it seriously
ask for water content
i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does, happy to be corrected