  • salt_bridge — update on the earlier thing is there a standard layout or does every lab do their own 13:27
  • truncation_tru — the related substances table is the interesting part. a row of "not detected" means they did not look hard 13:52
  • mhra_unlicensed — the three way match is vial, certificate, invoice. if all three agree you have something 14:09
  • karl_fischer — a supplier certificate on its own is a starting point, not evidence. that is the whole reason the verification channel exists 14:55
SB

unrelated but mixed fonts and inconsistent kerning in one document is worth a second look, i think

SB

the paperwork can be perfect and the vial can still be light. weigh it, i could be wrong

update on the earlier thing is there a standard layout or does every lab do their own

13

an identical chromatogram on two different lots is the single biggest tell there is, your mileage will differ

a certificate should name the method, the instrument, the column and the operator. most name none of those

*Janoshik not the other one

TT

sorry to jump in update from 7 months ago: started asking every supplier for water content and about half now include it, ymmv

not detected means nothing

check the lot

the related substances table is the interesting part. a row of "not detected" means they did not look hard

10

the certificate from TFC is the one i use to teach this because it actually has a populated impurity table

for the archive i have never seen a research certificate with an endotoxin result on it. not once

update on the earlier thing is endotoxin ever tested on research material

MU

the three way match is vial, certificate, invoice. if all three agree you have something

8🎉8👀1
TT

net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial

SB

two certificates from the same supplier have an identical chromatogram, is that normal

😂4

single wavelength detection can miss a co-eluting impurity that does not absorb there

one decimal versus two is usually just house style, not precision

📉1📈1

does anyone actually check the residual solvents section

good certificate actually

TT

i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does, take that with a pinch of salt

KF

a supplier certificate on its own is a starting point, not evidence. that is the whole reason the verification channel exists

🤝3😂14

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019

5

what does net peptide content mean next to gross mass

sloppy not sinister