  • bac_water_bill — if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not 18:10
  • cold_start_cy — residual solvents matter more than people think for anything that went through a lot of purification steps 18:23
  • cold_start_cy — update on the earlier thing my 2mg vial weighed more than 10mg of powder, is the certificate lying 19:13
  • ms_ms_mira — i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019 20:31
  • ms_ms_mira — coming back to this the retention time on this one is different from the last lot, problem 20:32
BW

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not

CS

residual solvents matter more than people think for anything that went through a lot of purification steps

thats a tell

CS

update on the earlier thing my 2mg vial weighed more than 10mg of powder, is the certificate lying

[edited]
MM

an identical chromatogram on two different lots is the single biggest tell there is

MM

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019

net not gross

why would a vial be 98.1 pure and still assay under label