  • evidence_or_not — for the archive tfa counterion runs higher by mass than acetate. if the certificate does not say, you cannot do the mass balance 20:14
  • customs_owl — my 20mg vial weighed more than 10mg of powder, is the certificate lying 21:44
  • VialBot — New independent result logged — QYB, lot F-1330, purity 99.2% (Janoshik). 21:50
EO

update on the earlier thing the honest summary is that a certificate tells you what the supplier says about a lot they chose to test

i have never seen a research certificate with an endotoxin result on it. not once

EO

water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it

SB

a vial can be 99.4% pure and hold 8.1mg of a 10mg label. both numbers are true and only one of them is the one you care about

for the archive tfa counterion runs higher by mass than acetate. if the certificate does not say, you cannot do the mass balance

💀4🤝8
NN

the three way match is vial, certificate, invoice. if all three agree you have something

i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does

AA

the font on this one changes halfway down, am i being paranoid

one decimal versus two is usually just house style, not precision, for what its worth
a supplier certificate on its own is a starting point, not evidence. that is the whole reason the verification channel exists

should a certificate say which instrument and method they used

GG

residual solvents matter more than people think for anything that went through a lot of purification steps

what does net peptide content mean next to gross mass

test it yourself

thats a real table

1📈1
NN

single wavelength detection can miss a co-eluting impurity that does not absorb there

CO

my 20mg vial weighed more than 10mg of powder, is the certificate lying

💀16⚠️12🙏12
DO

sterility and endotoxin are separate tests and almost nobody runs either on research material, i have it written down somewhere

VB

New independent result logged — QYB, lot F-1330, purity 99.2% (Janoshik).

📉2👀4
DO

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019