i was wrong about this last year: it is fine to draw cold, it just stings more going in
#reconstitution 2025-05-06
- two_ml_two — give it 8 minutes at room temperature before you decide it has not dissolved a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end… 15:26
- month_six_me — my vial pulled the water in on its own, is that the vacuum or did i do something 15:44
- two_ml_two — the last few units are a real loss. i accept it rather than tilting the vial and drawing air, ill dig out the number 16:31
- mg_per_ml — coming back after 18 months, has the pinned recon volume advice changed 17:01
- VialBot — Channel stats, last 30 days: 50 messages from 10 members. 17:32
genuine question it should be completely clear with no floaters. cloudy means stop
if you draw up with a bigger pin and inject with a fresh one you lose a bit more to dead space
clear or bin it
you can absolutely just always use 2ml, and honestly most of us should
yep 10 units
whats the smallest volume you would trust yourself to measure on a u100
check your maths
thats fine
20mg in 2ml is 10mg/ml. 1mg is 10 units, 2mg is 20 units, easy
give it 8 minutes at room temperature before you decide it has not dissolved
a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end up with
my 10mg vial weighed 11.4g on the jewellery scale, is that wrong
my vial pulled the water in on its own, is that the vacuum or did i do something
i use bac water even for a single-use vial because it stings less, which is not the reason it exists, your mileage will differ
sorry to jump in a slightly collapsed cake is cosmetic. a puddle in the bottom is not
one unit is 0.01ml. 100 units is 1ml. everything else in this channel follows from that
do not add more bac water to an already reconstituted vial, you have lost track of the concentration
one unit is 0.01ml. 100 units is 1ml. everything else in this channel follows from that
the last few units are a real loss. i accept it rather than tilting the vial and drawing air, ill dig out the number
coming back after 18 months, has the pinned recon volume advice changed
write the date on
for the archive pick the volume so your dose is a whole number of units. thats the entire trick
30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right
dead space
Channel stats, last 30 days: 50 messages from 10 members.
thats 5mg/ml
unrelated but can i add more bac water later to a vial ive already reconstituted
weigh it first
one unit is 0.01ml
update from 6 months ago: switched to a single concentration and have not miscalculated since
read it at eye level
a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end up with