you can absolutely just always use 2ml, and honestly most of us should
#reconstitution 2026-04-01
- noct.titrate — 10mg in 1ml is 10mg/ml, so 2.5mg is 25 units. thats the one i use 16:47
- turnaround_tam — my 10mg vial weighed 11.4g on the jewellery scale, is that wrong 17:34
- turnaround_tam — what do you do with the last 5 units when you cant draw them cleanly 17:48
- vialkeeper — if the maths gives you 13.7 units, change the volume. do not try to hit 13.7 19:26
- auckland_aliquot — do you draw up with the same pin you inject with 19:38
if i add 3ml to a 15mg vial what concentration am i actually at
check your maths
thats 5mg/ml
anyone got a photo of what a properly dissolved vial looks like
ok so my vial pulled the water in on its own, is that the vacuum or did i do something
how much do i lose to dead space with a 29G pin
label the vial
gross powder mass is not net peptide. water and counterion are in that number
i swirl for about thirty seconds and then leave it. never had one fail to dissolve, i think
update from 14 months ago: switched to a single concentration and have not miscalculated since
do you let it come to room temp before drawing or draw it cold
why does everyone say 2ml specifically and not 1ml
how long after reconstituting before its actually dissolved
10mg in 1ml is 10mg/ml, so 2.5mg is 25 units. thats the one i use
20mg in 2ml is 10mg/ml. 1mg is 10 units, 2mg is 20 units, easy
swirl dont shake
bac water
bacteriostatic water for anything multi-use. sterile water has no preservative in it at all
is the meniscus reading actually a real source of error or am i overthinking
does benzyl alcohol matter if im finishing the vial in one go
the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol
pick the volume so your dose is a whole number of units. thats the entire trick
my 10mg vial weighed 11.4g on the jewellery scale, is that wrong
what do you do with the last 5 units when you cant draw them cleanly
i have never once regretted using a rounder number and a slightly bigger volume
label the date too. you will not remember which vial is which by week 6, ask me again in a month
*Medutest not the other one
how do you all measure a half unit, or do you just not
unrelated but is a slightly cloudy solution ever ok or is that always a bin it
swirl it. do not shake it. the foam is denatured protein and you are not getting it back
lyophilised powder is far more robust than people think. it is the solution that is fragile, your mileage will differ
is there any reason not to just always use 2ml
a slightly collapsed cake is cosmetic. a puddle in the bottom is not, take that with a pinch of salt
New independent result logged — WXT, lot C-4402, purity 98.1% (VendorInvestigate).
dead space
clear or bin it
bac water or sterile water for something im going into weekly for 9 weeks
thats the vacuum
sanity check my maths before i pin myself with something stupid
i write the mg/ml on the vial with a sharpie the moment i reconstitute it
too dilute imo
round numbers
the last few units are a real loss. i accept it rather than tilting the vial and drawing air
if the maths gives you 13.7 units, change the volume. do not try to hit 13.7
the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol
a slightly collapsed cake is cosmetic. a puddle in the bottom is not
read it at eye level
do you draw up with the same pin you inject with
quick one temperature of the diluent does not matter. how fast you push it in does
slightly off topic but benzyl alcohol is what makes it bacteriostatic. it is about 0.9% typically, still working it out
does temperature of the bac water matter at all