  • salt_bridge — update from 23 months ago: started asking every supplier for water content and about half now include it 23:04
  • underfill_uma — is a supplier certificate worth anything on its own 23:08
  • batch_bandit — i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does, ask me again in a month 23:18
PP

a certificate should name the method, the instrument, the column and the operator. most name none of those

VB

Testing queue: 6 submissions open, 28 awaiting dispatch.

update from 23 months ago: started asking every supplier for water content and about half now include it

🤝15🧊2⚠️1
PP

if you only read one line on a certificate, read the lot number. if you read two, read the assay, thats one data point
the honest summary is that a certificate tells you what the supplier says about a lot they chose to test

BB

no lot number, no certificate. a document you cannot tie to the vial in your hand is decoration

whats the minimum a certificate has to have before you take it seriously

PP

a supplier certificate on its own is a starting point, not evidence. that is the whole reason the verification channel exists

i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does, ask me again in a month

🧊3📈5

for the archive no lot number on this certificate, does that make it worthless

BB

retention time shifts between runs are normal. relative retention time is the number to compare

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019

purity is what fraction of the contents is the target. assay is how many mg are actually there. different questions
i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does

same chromatogram

LM

water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it

while im here the font on this one changes halfway down, am i being paranoid

SB

net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial, we shall see

LM

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not