#coa-reading 2026-05-25

Monday44 messages10 participantstimes are UTC
Highlights from this day
  • gip_glp_gil — that is exactly the assumption the whole trade runs on 15:09
  • assay_not_purity — depends entirely who made it. rough shape of what people have seen: 16:16
  • deadspace — splitting this off, it deserves its own space 16:35
  • deadspace — and trust is fine as long as you call it trust and not evidence 16:50
RR

the paperwork can be perfect and the vial can still be light. weigh it

🔥12

the related substances table is the interesting part. a row of "not detected" means they did not look hard

SB

i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does, still working it out

SB

right so if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not

tfa or acetate, how do i tell from the paperwork

follow up a certificate should name the method, the instrument, the column and the operator. most name none of those

⚠️173💀11

water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it

is a supplier certificate worth anything on its own
i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019

SB

mixed fonts and inconsistent kerning in one document is worth a second look, i have it written down somewhere
the related substances table is the interesting part. a row of "not detected" means they did not look hard

VB

Testing queue: 3 submissions open, 36 awaiting dispatch.

TM

unrelated but residual solvents matter more than people think for anything that went through a lot of purification steps

the retention time on this one is different from the last lot, problem

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019

lot        bought    purity   assay/label
A-2418     2025-03   99.1%    9.6 / 10mg
A-2601     2025-08   98.7%    9.8 / 10mg
B-0114     2026-01   99.3%    9.4 / 10mg
B-0329     2026-04   98.9%    9.9 / 10mg
DE

because without one the document cannot be attached to anything

AN

a lot number is the join key. it is what lets you say this paper and this vial are the same event

no lot number and you have a nice chromatogram of something, somewhere, once

GG

i asked a vendor for the lot on my vial and they sent the same PDF back with a different number typed in the corner. same chromatogram, same integration table, same retention times

DE

thats the giveaway. real reruns never land on identical retention times to two decimals

AN

they land close. 12.41 vs 12.44 vs 12.39 across three injections is normal. identical to the hundredth across two separate lots weeks apart is not a coincidence, it is a copy

GG

same-trace-two-lots-overlay.png
1440×900 · 288 KB · not retained in the public archive

overlaid them, they are pixel identical apart from the lot field

AN

depends entirely who made it. rough shape of what people have seen:

SourceLot style seenTraceable?
Bachem Holdingalphanumeric with a year blockyes, QA answers on it
Chinese Peptide Companyprefix + sequentialsometimes, if you are a real account
Wuhan Wanshengprefix + date-codedreseller-dependent
GGPepsshort numeric, reseller-assignedusually no
anonymous reseller PDFhandwritten or absentno

and to be clear, reseller-assigned is not automatically dishonest. a reseller genuinely may not know the manufacturer lot

DE

which is its own problem. if they do not know it, neither do you, so nobody can ever compare two of your orders

DE

you keep your own records. lot if given, order date, vendor, and any test you paid for. after four or five orders you have a dataset nobody sold you

GG

worth saying: cpcbio and bachemholding are the two where i have personally had a lot number confirmed by someone who works there. everything else is trust

DE

and trust is fine as long as you call it trust and not evidence

12