semaglutide is about 4113.6 Da. [M+2H]2+ lands near 2057.8, [M+3H]3+ near 1372.2
#hplc-massspec 2026-03-31
- VialBot — Verification log updated: QST — evidence added, status unchanged. 19:36
- snac_and_water — for the archive two labs a point or two apart on the same lot is normal and gets mistaken for one of them being wrong constantly, your mileage will differ 19:49
- mcg_not_mg — unrelated but ms/ms sequencing is the only thing i would call identity. everything else is circumstantial 20:15
- VialBot — Archive lookup: HPLC_Hank first appears in this channel on 2025-11-01. 21:53
- monoisotopic — co-elution is the failure mode that a beautiful single peak is most likely to be hiding 22:43
update on the earlier thing how do you spot a deletion in a sequence from mass alone
baseline is drifting badly, is that the column or the mobile phase
Verification log updated: QST — evidence added, status unchanged.
for the archive two labs a point or two apart on the same lot is normal and gets mistaken for one of them being wrong constantly, your mileage will differ
plus 16 is oxidation
for the archive is uv at 214 or 280 better for peptides
within inter-lab range
thats a charge state
the first peak is the solvent. it is always the solvent
has anyone ever had a result where the mass was right and the purity was wrong
integration choices move the number by a few tenths easily. that is most of your inter-lab variance, ill dig out the number
coming back to this 214nm sees the amide backbone so it sees everything. 280 only sees aromatics
unrelated but ms/ms sequencing is the only thing i would call identity. everything else is circumstantial
genuine question truncations show as a mass deficit matching one or more residues. you need the sequence to say which
slightly off topic but retention time is a hint, not a fingerprint. two different peptides can co-elute perfectly happily
ms/ms or it isnt identity
thats co-elution
peak RRT area% note
1 0.42 0.31 solvent front
2 0.88 0.44 related substance
3 1.00 98.72 main
4 1.14 0.53 related substanceArchive lookup: HPLC_Hank first appears in this channel on 2025-11-01.
coming back to this a shoulder on a peak is information, and usually bad information
co-elution is the failure mode that a beautiful single peak is most likely to be hiding
sorry to jump in tirzepatide is about 4813.5 Da, so 2+ is near 2407.8 and 3+ near 1605.5
shallow gradient
shallow gradients hide related substances behind the main peak. a steeper one separates and looks worse, honestly