  • two_lifts_a_week — took me a year to stop over-diluting. the measurement error at 4 units is worse than the convenience 21:37
  • panel_before_after — what do you do with the last 30 units when you cant draw them cleanly 21:41
  • bea_reconstitutes — gross powder mass is not net peptide. water and counterion are in that number 21:54
  • bea_reconstitutes — nobody here should be telling you a dose. we can check your arithmetic, thats a different thing 22:02
  • lyophile_liv — give it 4 minutes at room temperature before you decide it has not dissolved 23:03
TT

whats the smallest volume you would trust yourself to measure on a u100

one unit is 0.01ml

🤝1

genuine question it should be completely clear with no floaters. cloudy means stop, i could be wrong

does temperature of the bac water matter at all

i write the mg/ml on the vial with a sharpie the moment i reconstitute it

📈1

*mg/ml, obviously

BB

one unit is 0.01ml. 100 units is 1ml. everything else in this channel follows from that

if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration

5mg in 2ml gives 2.5mg/ml, 0.25mg is 10 units. good for a starting dose, i have it written down somewhere

21:24ferrous_ash pinned a message to this channel
BR

i was wrong about this last year: it is fine to draw cold, it just stings more going in

anyone else find the 30mg vials harder to get fully dissolved than the small ones

weighing the vial before you reconstitute is the only way to catch an underfill, anyway

😂1
TL

took me a year to stop over-diluting. the measurement error at 4 units is worse than the convenience

😂3👀6

how much do i lose to dead space with a 31G pin

my rule is one concentration for everything so i never have to think about it at 7am
update from 25 months ago: switched to a single concentration and have not miscalculated since

thats the vacuum

AA

is a slightly cloudy solution ever ok or is that always a bin it

write the date on

i keep a spare vial of bac water in the fridge purely so i never rush the maths

nobody here should be telling you a dose. we can check your arithmetic, thats a different thing

⚠️4👀12😂7

do i swirl for a specific length of time or just until its clear

AA

the last few units are a real loss. i accept it rather than tilting the vial and drawing air, i could be wrong

30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right

read it at eye level

🤝11
22:21ferrous_ash pinned a message

ok so coming back after 8 months, has the pinned recon volume advice changed

is it worth buying a 3ml syringe for the diluent or is the insulin one fine

anyone worked out a recon volume that puts 0.25mg on a round unit mark

BW

unrelated but if the maths gives you 13.7 units, change the volume. do not try to hit 13.7

quick one the meniscus thing is real. read it at eye level or you are guessing by a unit either way

LL

if the powder is on the stopper, tap it down before you add anything. it will still dissolve either way

LL

give it 4 minutes at room temperature before you decide it has not dissolved

📈6

15mg in 3ml is 5mg/ml. same numbers as 10 in 2, just more of it

is the meniscus reading actually a real source of error or am i overthinking

TL

i use bac water even for a single-use vial because it stings less, which is not the reason it exists