whats the smallest volume you would trust yourself to measure on a u100
#reconstitution 2024-10-28
Monday9 messages3 participantstimes are UTC
Highlights from this day
- vacuum_vic — while im here if the maths gives you 13.7 units, change the volume. do not try to hit 13.7 22:14
- vacuum_vic — dead space in a standard insulin syringe hub is small but it is not nothing over a month 22:15
- vacuum_vic — i was wrong about this last year: it is fine to draw cold, it just stings more going in 22:31
- residual_solvent — unrelated but bacteriostatic water for anything multi-use. sterile water has no preservative in it at all, i think 23:37
while im here if the maths gives you 13.7 units, change the volume. do not try to hit 13.7
dead space in a standard insulin syringe hub is small but it is not nothing over a month
❤️2✅9😂5
coming back to this sanity check my maths before i pin myself with something stupid
[edited]i was wrong about this last year: it is fine to draw cold, it just stings more going in
too dilute imo
aim the diluent at the glass wall, not at the powder. it goes in gentler
check your maths
unrelated but bacteriostatic water for anything multi-use. sterile water has no preservative in it at all, i think