vialroom

#reconstitution 2025-08-15

Friday45 messages10 participantstimes are UTC
Highlights from this day
  • chlorhex — i swirl for about thirty seconds and then leave it. never had one fail to dissolve 16:26
  • u100_pat — is there any reason not to just always use 2ml 17:19
  • courier_vs_post — unrelated but how do you all measure a half unit, or do you just not 17:30
  • chlorhex — you can absolutely just always use 2ml, and honestly most of us should, i think 18:39
  • snac_and_water — the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol, take that with a pinch of salt bacteriostatic water for anything multi-use.… 21:51
U1

gross powder mass is not net peptide. water and counterion are in that number

U1

aim the diluent at the glass wall, not at the powder. it goes in gentler

CH

i swirl for about thirty seconds and then leave it. never had one fail to dissolve

👀9

10mg in 1ml is 10mg/ml, so 2.5mg is 25 units. thats the one i use

CH

10mg in 2ml is 5mg/ml. so 0.5mg is 0.1ml which is 10 units on a u100

RR

if you draw up with a bigger pin and inject with a fresh one you lose a bit more to dead space

17:06chlorhex pinned a message to this channel
CH

my rule is one concentration for everything so i never have to think about it at 7am, thats just me

U1

is there any reason not to just always use 2ml

12😂14

read it at eye level

label the date too. you will not remember which vial is which by week 31

NP

a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end up with

TS

if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration

TS

temperature of the diluent does not matter. how fast you push it in does

CH

you can absolutely just always use 2ml, and honestly most of us should, i think

👀1🤝10🔥15

the meniscus thing is real. read it at eye level or you are guessing by a unit either way

benzyl alcohol is what makes it bacteriostatic. it is about 0.9% typically

CH

30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right, someone check my working

🔥3
TS

20mg in 2ml is 10mg/ml. 1mg is 10 units, 2mg is 20 units, easy
nobody here should be telling you a dose. we can check your arithmetic, thats a different thing

a slightly collapsed cake is cosmetic. a puddle in the bottom is not

i keep a spare vial of bac water in the fridge purely so i never rush the maths

MC

it should be completely clear with no floaters. cloudy means stop

U1

nobody here should be telling you a dose. we can check your arithmetic, thats a different thing

MC

if i add 3ml to a 40mg vial what concentration am i actually at

MC

genuine question i have never once regretted using a rounder number and a slightly bigger volume

20:54chlorhex pinned a message to this channel
SA

do not add more bac water to an already reconstituted vial, you have lost track of the concentration

whats the smallest volume you would trust yourself to measure on a u100

OW

if the maths gives you 13.7 units, change the volume. do not try to hit 13.7

CH

i write the mg/ml on the vial with a sharpie the moment i reconstitute it
label the date too. you will not remember which vial is which by week 30

CH

lyophilised powder is far more robust than people think. it is the solution that is fragile

21:49chlorhex pinned a message to this channel
SA

the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol, take that with a pinch of salt
bacteriostatic water for anything multi-use. sterile water has no preservative in it at all

[edited]
CH

anyone worked out a recon volume that puts 2.5mg on a round unit mark